Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/9940
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNikfarjam, Mehrdaden
dc.contributor.authorMalcontenti-Wilson, Caterinaen
dc.contributor.authorChristophi, Christopheren
dc.date.accessioned2015-05-15T23:13:52Z
dc.date.available2015-05-15T23:13:52Z
dc.date.issued2005-06-01en
dc.identifier.citationPhotomedicine and Laser Surgery; 23(3): 284-8en
dc.identifier.govdoc15954816en
dc.identifier.otherPUBMEDen
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/9940en
dc.description.abstractInterstitial laser thermotherapy (ILT) of liver tumors is generally performed using neodyium yttrium-aluminium-garnet (Nd-YAG) lasers. More versatile diode units, developed predominantly for other clinical applications, may be equally suitable for ILT. This study compares the efficacy of diode and Nd-YAG lasers in achieving maximum tissue necrosis, at low power, in a murine model.Thermal ablation was induced in the liver of CBA strain mice by diode (980-nm wavelength) and Nd-YAG (1064-nm wavelength) lasers using 400-microm diameter bare fibers. Treatment time prior to tissue charring was determined for both lasers at a power output of 2 W. Tissue temperature was recorded upon completion of therapy 3 mm from the fiber insertion site. The maximum diameter of necrosis was accurately assessed by nicotinamide adenine dinucleotide (NADH) diaphorase tissue staining.Maximum diameter of tissue necrosis prior to charring occurred at 20 s (40 J) with the diode laser compared to 50 s (100 J) with the Nd-YAG laser. The maximum diameter of necrosis (mean [SEM]) produced by the diode laser, 5.9 mm (0.14), was equivalent to the necrosis induced by the Nd-YAG laser, 5.9 mm (0.14) (p = 0.963). Tissue temperature 3 mm from the fiber application site immediately following ILT in the diode laser group, 40.8 degrees C (0.93), was not statistically different than that of the Nd-YAG laser group, 39.0 degrees C (0.86) (p = 0.452). Tissue charring consistently prevented treatment beyond 20 s at 2W by the diode laser.Low power ILT with diode and Nd-YAG lasers achieves equivalent maximal necrosis when applied to the liver by a bare fiber. Treatment time to produce maximal necrosis is however significantly shorter with the diode laser.en
dc.language.isoenen
dc.subject.otherAnimalsen
dc.subject.otherHyperthermia, Induceden
dc.subject.otherLaser Coagulationen
dc.subject.otherLasersen
dc.subject.otherLiver.pathologyen
dc.subject.otherMaleen
dc.subject.otherMiceen
dc.subject.otherMice, Inbred CBAen
dc.subject.otherNecrosisen
dc.titleComparison of 980- and 1064-nm wavelengths for interstitial laser thermotherapy of the liver.en
dc.typeJournal Articleen
dc.identifier.journaltitlePhotomedicine and laser surgeryen
dc.identifier.affiliationDepartment of Surgery, University of Melbourne, Austin Hospital, Melbourne, Victoria, Australiaen
dc.identifier.doi10.1089/pho.2005.23.284en
dc.description.pages284-8en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/15954816en
dc.type.austinJournal Articleen
local.name.researcherChristophi, Christopher
item.grantfulltextnone-
item.openairetypeJournal Article-
item.languageiso639-1en-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.deptSurgery (University of Melbourne)-
crisitem.author.deptSurgery-
crisitem.author.deptHepatopancreatobiliary Surgery-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

36
checked on Nov 18, 2024

Google ScholarTM

Check