Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/34397
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCutuli, Salvatore L-
dc.contributor.authorSee, Emily J-
dc.contributor.authorOsawa, Eduardo A-
dc.contributor.authorAncona, Paolo-
dc.contributor.authorMarshall, David-
dc.contributor.authorEastwood, Glenn M-
dc.contributor.authorGlassford, Neil J-
dc.contributor.authorBellomo, Rinaldo-
dc.date2023-
dc.date.accessioned2023-12-13T05:24:40Z-
dc.date.available2023-12-13T05:24:40Z-
dc.date.issued2021-03-
dc.identifier.citationCritical Care and Resuscitation : Journal of the Australasian Academy of Critical Care Medicine 2021-03; 23(1)en_US
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/34397-
dc.description.abstractObjective: Non-invasive thermometers are widely used in both clinical practice and trials to estimate core temperature. We aimed to investigate their accuracy and precision in patients admitted to the intensive care unit (ICU). Study design: Systematic review and meta-analysis. Data sources: We searched MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials to identify all relevant studies from 1966 to 2017. We selected published trials that reported the accuracy and precision of non-invasive peripheral thermometers (index test) in ICU patients compared with intravascular temperature measurement (reference test). The extracted data included the study design and setting, authors, study population, devices, and body temperature measurements. Methods: Two reviewers performed the initial search, selected studies, and extracted data. Study quality was assessed using the QUADAS-2 tool. Pooled estimates of the mean bias between index and reference tests and the standard deviation of mean bias were synthesised using DerSimonian and Laird random effects meta-analyses. Results: We included 13 cohort studies (632 patients, 105 375 measurements). Axillary, tympanic infrared and zero heat flux thermometers all underestimated intravascular temperature. Only oesophageal measurements showed clinically acceptable accuracy. We found an insufficient number of studies to assess precision for any technique. Study heterogeneity was high (99-100%). Risk of bias for the index test was unclear, mostly because of no device calibration or control for confounders. Conclusions: Compared with the gold standard of intravascular temperature measurement, non-invasive peripheral thermometers have low accuracy. This makes their clinical and trial-related use in ICU patients unreliable and potentially misleading.en_US
dc.language.isoeng-
dc.titleAccuracy of non-invasive body temperature measurement methods in adult patients admitted to the intensive care unit: a systematic review and meta-analysis.en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleCritical Care and Resuscitation : Journal of the Australasian Academy of Critical Care Medicineen_US
dc.identifier.affiliationDipartimento di Scienze dell'Emergenza, Anestesiologiche e della Rianimazione; UOC di Anestesia, Rianimazione, Terapia Intensiva e Tossicologia Clinica; Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome; Istituto di Anestesia e Rianimazione; Università Cattolica del Sacro Cuore, Rome, Italy.en_US
dc.identifier.affiliationSchool of Medicine, University of Melbourne, Melbourne, VIC, Australia.en_US
dc.identifier.affiliationIntensive Careen_US
dc.identifier.affiliationCentre for Integrated Critical Care, School of Medicine, University of Melbourne, Melbourne, VIC, Australia.en_US
dc.identifier.doi10.51893/2021.1.SR1en_US
dc.type.contentTexten_US
dc.identifier.pubmedid38046384-
dc.description.volume23-
dc.description.issue1-
dc.description.startpage6-
dc.description.endpage13-
item.openairetypeJournal Article-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.grantfulltextnone-
crisitem.author.deptIntensive Care-
crisitem.author.deptIntensive Care-
crisitem.author.deptIntensive Care-
crisitem.author.deptIntensive Care-
crisitem.author.deptData Analytics Research and Evaluation (DARE) Centre-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

50
checked on Jan 27, 2025

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.