Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/32604
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGopaul, Urvashy-
dc.contributor.authorLaver, Derek-
dc.contributor.authorCarey, Leeanne M-
dc.contributor.authorMatyas, Thomas-
dc.contributor.authorvan Vliet, Paulette-
dc.contributor.authorCallister, Robin-
dc.date2023-
dc.date.accessioned2023-04-14T02:47:07Z-
dc.date.available2023-04-14T02:47:07Z-
dc.date.issued2023-03-20-
dc.identifier.citationSensors (Basel, Switzerland) 2023; 23(6)en_US
dc.identifier.issn1424-8220-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/32604-
dc.description.abstractSensor-based devices can record pressure or force over time during grasping and therefore offer a more comprehensive approach to quantifying grip strength during sustained contractions. The objectives of this study were to investigate the reliability and concurrent validity of measures of maximal tactile pressures and forces during a sustained grasp task using a TactArray device in people with stroke. Participants with stroke (n = 11) performed three trials of sustained maximal grasp over 8 s. Both hands were tested in within- and between-day sessions, with and without vision. Measures of maximal tactile pressures and forces were measured for the complete (8 s) grasp duration and plateau phase (5 s). Tactile measures are reported using the highest value among three trials, the mean of two trials, and the mean of three trials. Reliability was determined using changes in mean, coefficients of variation, and intraclass correlation coefficients (ICCs). Pearson correlation coefficients were used to evaluate concurrent validity. This study found that measures of reliability assessed by changes in means were good, coefficients of variation were good to acceptable, and ICCs were very good for maximal tactile pressures using the average pressure of the mean of three trials over 8 s in the affected hand with and without vision for within-day sessions and without vision for between-day sessions. In the less affected hand, changes in mean were very good, coefficients of variations were acceptable, and ICCs were good to very good for maximal tactile pressures using the average pressure of the mean of three trials over 8 s and 5 s, respectively, in between-day sessions with and without vision. Maximal tactile pressures had moderate correlations with grip strength. The TactArray device demonstrates satisfactory reliability and concurrent validity for measures of maximal tactile pressures in people with stroke.en_US
dc.language.isoeng-
dc.subjectconcurrent validityen_US
dc.subjectfinger forcesen_US
dc.subjectpressure sensorsen_US
dc.subjectreliabilityen_US
dc.subjectstrokeen_US
dc.subjectsustained graspen_US
dc.subjecttactileen_US
dc.titleMeasures of Maximal Tactile Pressures during a Sustained Grasp Task Using a TactArray Device Have Satisfactory Reliability and Concurrent Validity in People with Stroke.en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleSensors (Basel, Switzerland)en_US
dc.identifier.affiliationKITE Research-Toronto Rehabilitation Institute, University Health Network, Toronto, ON M5G 2A2, Canada.en_US
dc.identifier.affiliationHuman Physiology, School of Biomedical Sciences & Pharmacy, College of Health, Medicine and Wellbeing, University of Newcastle, Callaghan, NSW 2308, Australia.en_US
dc.identifier.affiliationOccupational Therapy, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne Campus, Melbourne, VIC 3086, Australia.en_US
dc.identifier.affiliationSchool of Health Sciences, College of Health, Medicine and Wellbeing, University of Newcastle, Newcastle, NSW 2308, Australia.en_US
dc.identifier.affiliationThe Florey Institute of Neuroscience and Mental Healthen_US
dc.identifier.doi10.3390/s23063291en_US
dc.type.contentTexten_US
dc.identifier.orcid0000-0002-1544-5155en_US
dc.identifier.orcid0000-0001-6376-8613en_US
dc.identifier.pubmedid36992002-
dc.description.volume23-
dc.description.issue6-
local.name.researcherCarey, Leeanne M
item.languageiso639-1en-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.deptThe Florey Institute of Neuroscience and Mental Health-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

28
checked on Nov 8, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.