Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/25135
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLin, Natalie Chew Jin-
dc.contributor.authorHayward, Kathryn S-
dc.contributor.authorD'Cruz, Kate-
dc.contributor.authorThompson, Eloise-
dc.contributor.authorLi, Xia-
dc.contributor.authorLannin, Natasha A-
dc.date2019-04-23-
dc.date.accessioned2020-10-27T03:57:15Z-
dc.date.available2020-10-27T03:57:15Z-
dc.date.issued2020-11-
dc.identifier.citationDisability and Rehabilitation 2020; 42(22): 3243-3249en
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/25135-
dc.description.abstractPurpose: To demonstrate the validity and reliability of a smartphone app to measure ROM after stroke.Materials and methods: Twenty-one stroke survivors with a diagnosis of stroke that affected the motor cortex or subcortical motor pathways and were hospital inpatients at one of two metropolitan hospitals were recruited. A within-session test-retest design was used to compare ROM measurements taken using the GetMyROM app for iPhone to those taken by a digital inclinometer. Torque-controlled passive elbow and wrist extension were collected and statistical analysis of concurrent validity and test-retest reliability performed.Results: GetMyROM app was valid when compared to the digital inclinometer for measuring passive ROM of the elbow (r = .98, p = .0001, ICC  =  0.97) and wrist (r = .97, p = .0001, ICC  =  0.96) in individuals with acute stroke. Both the GetMyROM app and inclinometer demonstrated excellent test-retest reliability: ICC values are 0.84 to 0.93, and standard error of measurement between 6° to 10°.Conclusion: The GetMyROM app may be implemented in a clinical setting similar to that where the study was conducted, enabling rehabilitation physicians and therapists to use a smartphone to take precise measurements of ROM in daily clinical practice.Implications for rehabilitationApproximately half of all stroke survivors experience reduced passive upper limb range of movement.Accurate measurement of passive upper limb range of movement using validated assessments and/or instruments is paramount.This study demonstrates that the GetMyROM app is valid and reliable compared to the gold standard comparison (digital inclinometer), and is therefore appropriate to use in clinical settings to take precise measurements.en
dc.language.isoeng-
dc.subjectTechnologyen
dc.subjectrange of movementen
dc.subjectreliabilityen
dc.subjectStrokeen
dc.subjectupper limben
dc.subjectvalidityen
dc.titleValidity and reliability of a smartphone inclinometer app for measuring passive upper limb range of motion in a stroke population.en
dc.typeJournal Articleen
dc.identifier.journaltitleDisability and Rehabilitationen
dc.identifier.affiliationDepartment of Occupational Therapy, Singapore General Hospital, Bukit Merah, Singaporeen
dc.identifier.affiliationThe Florey Institute of Neuroscience and Mental Healthen
dc.identifier.affiliationSchool of Engineering and Mathematical Sciences, La Trobe University, Bundoora, VIC, Australiaen
dc.identifier.affiliationSchool of Allied Health, La Trobe University, Bundoora, VIC, Australiaen
dc.identifier.affiliationDepartment of Occupational Therapy, Alfred Health, Melbourne, VIC, Australiaen
dc.identifier.affiliationDepartment of Occupational Therapy, Royal Melbourne Hospital, Parkville, VIC, Australiaen
dc.identifier.doi10.1080/09638288.2019.1585972en
dc.type.contentTexten
dc.identifier.orcid0000-0001-5240-3264en
dc.identifier.orcid0000-0002-5155-1350en
dc.identifier.orcid0000-0002-2066-8345en
dc.identifier.pubmedid33084443-
local.name.researcherHayward, Kathryn S
item.languageiso639-1en-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.deptThe Florey Institute of Neuroscience and Mental Health-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

132
checked on Nov 9, 2024

Google ScholarTM

Check