Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/24457
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAykanat, V M-
dc.contributor.authorBroadbent, Eloise-
dc.contributor.authorPeyton, Philip J-
dc.date2020-08-26-
dc.date.accessioned2020-09-28T20:40:02Z-
dc.date.available2020-09-28T20:40:02Z-
dc.date.issued2021-04-
dc.identifier.citationAnaesthesia 2021; 76(4): 514-519en
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/24457-
dc.description.abstractPeri-operative hypothermia is associated with significant morbidity, yet limitations exist regarding non-invasive temperature assessment in the post-anaesthesia care unit (PACU). In this prospective study of 100 patients, we aimed to determine the reliability of two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, in addition to an indwelling urinary catheter with temperature probe, in comparison with the final nasopharyngeal core temperature at the end of surgery. Agreement of forehead measurement with nasopharyngeal temperature showed a mean bias (±95% limits of agreement) of 0.15 °C (±1.4 °C), with a steep slope of the relationship on the Bland-Altman plot of -0.8, indicating a tendency to normalise patient temperature readings to 36.4 °C. Only 54% of hypothermic cases were correctly detected by the forehead measurement device. Agreement of tympanic measurement with nasopharyngeal core temperature measurement was marginally improved with a mean bias of 0.13 °C (95% limits of agreement ±1.15 °C). In contrast, agreement of bladder temperature with nasopharyngeal temperature showed a mean (SD) bias of 0.19 (0.28) °C (95% limits of agreement ±0.54 °C), with a relatively flat line of best fit. We demonstrated that two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, compared with nasopharyngeal core temperature, were imprecise and unreliable following major surgery. However, the indwelling catheter with temperature sensor was precise and acceptable for continuous core temperature measurement in the PACU.en
dc.language.isoeng-
dc.subjectcomplicationsen
dc.subjectmeasurementen
dc.subjectperi-operative hypothermiaen
dc.subjectquality and safetyen
dc.titleReliability of alternative devices for postoperative patient temperature measurement: two prospective, observational studies.en
dc.typeJournal Articleen
dc.identifier.journaltitleAnaesthesiaen
dc.identifier.affiliationAustin Healthen
dc.identifier.affiliationAnaesthesiaen
dc.identifier.doi10.1111/anae.15248en
dc.type.contentTexten
dc.identifier.orcid0000-0002-3936-6128en
dc.identifier.pubmedid32845016-
local.name.researcherBroadbent, Eloise
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.languageiso639-1en-
crisitem.author.deptAnaesthesia-
crisitem.author.deptAnaesthesia-
crisitem.author.deptInstitute for Breathing and Sleep-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

30
checked on Oct 2, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.