Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/22742
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Castle-Kirszbaum, Mendel | - |
dc.contributor.author | Maingard, Julian T | - |
dc.contributor.author | Lim, Ruth P | - |
dc.contributor.author | Barras, Christen D | - |
dc.contributor.author | Kok, Hong Kuan | - |
dc.contributor.author | Chandra, Ronil V | - |
dc.contributor.author | Chong, Winston | - |
dc.contributor.author | Asadi, Hamed | - |
dc.date | 2020-03-06 | - |
dc.date.accessioned | 2020-03-10T22:06:19Z | - |
dc.date.available | 2020-03-10T22:06:19Z | - |
dc.date.issued | 2020-09 | - |
dc.identifier.citation | Neurosurgery 2020; 87(3): 453-465 | en |
dc.identifier.uri | https://ahro.austin.org.au/austinjspui/handle/1/22742 | - |
dc.description.abstract | Treatment of unruptured intracranial aneurysms can reduce the risk of subarachnoid hemorrhage and its associated morbidity and mortality. However, current methods to predict the risk of rupture and optimize treatment strategies for intracranial aneurysms are limited. Assessment of intra-aneurysmal flow using 4-dimensional magnetic resonance imaging (4D MRI) is a novel tool that could be used to guide therapy. A systematic search of the literature was performed to provide a state-of-the-art review on 4D MRI assessment of unruptured intracranial aneurysms. A total of 18 studies were available for review. Eccentric flow on 4D MRI is associated with a greater aspect ratio and peak wall shear stress (WSS). WSS, vorticity, and peak velocity are greater in saccular than fusiform aneurysms. Unstable aneurysms are associated with greater WSS, peak wall stress, and flow jet angle and may exhibit wall enhancement. In comparison to computational fluid dynamics (CFD), 4D MRI has a lower spatial resolution and reports lower WSS and velocity magnitudes, but these parameters equalize when spatial resolution is matched. 4D MRI demonstrates the intra-aneurysmal hemodynamic changes associated with flow diversion, including significantly decreased flow velocity. Thus, 4D MRI is a novel, noninvasive imaging tool used for the evaluation of hemodynamics within intracranial aneurysms. Hemodynamic indices derived from 4D MRI appear to correlate well with the simulated (CFD) values and may be used to measure the success of endovascular therapies and risk factors for aneurysm growth and rupture. | en |
dc.language.iso | eng | - |
dc.subject | 4D | en |
dc.subject | Aneurysm | en |
dc.subject | CFD | en |
dc.subject | Cerebrovascular | en |
dc.subject | MRI | en |
dc.title | Four-Dimensional Magnetic Resonance Imaging Assessment of Intracranial Aneurysms: A State-of-the-Art Review. | en |
dc.type | Journal Article | en |
dc.identifier.journaltitle | Neurosurgery | en |
dc.identifier.affiliation | Department of Neurosurgery, Monash Health, Melbourne, Australia | en |
dc.identifier.affiliation | Austin Health, Heidelberg, Victoria, Australia | en |
dc.identifier.affiliation | The University of Melbourne, Melbourne, Australia | en |
dc.identifier.affiliation | NeuroInterventional Radiology Unit, Monash Health, Melbourne, Australia | en |
dc.identifier.affiliation | Department of Imaging, Monash Health, Melbourne, Australia | en |
dc.identifier.affiliation | Monash University, Melbourne, Australia | en |
dc.identifier.affiliation | School of Medicine, Deakin University, Victoria, Australia | en |
dc.identifier.affiliation | Department of Radiology Northern Health, Melbourne, Australia | en |
dc.identifier.affiliation | Department of Radiology, Royal Adelaide Hospital, The University of Adelaide, Australia | en |
dc.identifier.affiliation | South Australian Health and Medical Research Institute, Adelaide, Australia | en |
dc.identifier.doi | 10.1093/neuros/nyaa021 | en |
dc.type.content | Text | en |
dc.identifier.orcid | 0000-0003-2475-9727 | en |
dc.identifier.orcid | 0000-0001-8958-2411 | en |
dc.identifier.pubmedid | 32140714 | - |
dc.type.austin | Journal Article | - |
local.name.researcher | Asadi, Hamed | |
item.languageiso639-1 | en | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Journal Article | - |
crisitem.author.dept | Radiology | - |
crisitem.author.dept | Radiology | - |
Appears in Collections: | Journal articles |
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.