Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/20269
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYastrebov, Konstantin-
dc.contributor.authorAneman, Anders-
dc.contributor.authorSlama, Michel-
dc.contributor.authorKokhno, Vladimir-
dc.contributor.authorLuchansky, Vsevolod-
dc.contributor.authorOrde, Sam-
dc.contributor.authorHilton, Andrew K-
dc.contributor.authorLukiyanov, Dmitriy-
dc.contributor.authorVolobueva, Irina-
dc.contributor.authorSidelnikova, Svetlana-
dc.contributor.authorPolovnikov, Evgeniy-
dc.date2019-01-15-
dc.date.accessioned2019-02-04T23:34:15Z-
dc.date.available2019-02-04T23:34:15Z-
dc.date.issued2019-05-
dc.identifier.citationActa Anaesthesiologica Scandinavica 2019; 63(5): 594-600-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/20269-
dc.description.abstractThe distending intravascular pressure at no flow conditions reflects the stressed volume. While this haemodynamic variable is recognised as clinically important, there is a paucity of reports of its range and responsiveness to volume expansion in patients without cardiovascular disease and no reports of correlations to echocardiographic assessments of left ventricular filling. Twenty-seven awake (13 male), spontaneously breathing patients without any history of cardiopulmonary, vascular or renal disease were studied prior to induction of anaesthesia. The no-flow equilibrium pressure in the arm following rapid circulatory occlusion (Parm ) was measured via a radial arterial catheter. Transthoracic echocardiography was used to measure left ventricular end diastolic area and volume as well as the diameter of the inferior vena cava. The Parm and echocardiographic variables were measured before and after administration of 500 mL 0.9% NaCl over 10 minutes. Changes were analysed by paired t test, Pearson's correlation and multiple linear regression. Parm increased overall from 22 ± 5 mm Hg to 25 ± 6 mm Hg (mean difference 3.0 ± 4.5 mm Hg, P = 0.002) following the fluid bolus with corresponding increases in arterial pressure and echocardiographic variables. Variability in the direction of the Parm response reflected concomitant changes in vascular compliance. Only weak correlations were observed between changes in Parm and inferior vena cava diameter indexed to body surface area (R2  = 0.29, P = 0.01). Preoperative measurements of Parm increased following acute expansion of the intravascular volume. Echocardiography demonstrated poor correlation with Parm .-
dc.language.isoeng-
dc.subjectechocardiography-
dc.subjectfluid bolus-
dc.subjectmean systemic filling pressure-
dc.titleThe stop-flow arm equilibrium pressure in preoperative patients: Stressed volume and correlations with echocardiography.-
dc.typeJournal Article-
dc.identifier.journaltitleActa Anaesthesiologica Scandinavica -
dc.identifier.affiliationSt George Hospital, Sydney, New South Wales, Australiaen
dc.identifier.affiliationNovosibirsk Government Medical University, Novosibirsk, Russiaen
dc.identifier.affiliationFederal Center for Neurosurgery, Novosibirsk, Russiaen
dc.identifier.affiliationNovosibirsk Regional University Hospital, Novosibirsk, Russiaen
dc.identifier.affiliationLiverpool Hospital, Liverpool, New South Wales, Australiaen
dc.identifier.affiliationFaculty of Medicine and Health Sciences, Macquarie University, Sydney, New South Wales, Australiaen
dc.identifier.affiliationUniversity Hospital of Amiens and INSERM 1088, University of Picardie Jules Verne, Amiens, Franceen
dc.identifier.affiliationAustin Health, Heidelberg, Victoria, Australiaen
dc.identifier.affiliationNepean Hospital, Penrith, Sydney, New South Wales, Australiaen
dc.identifier.affiliationFaculty of Medicine, The University of New South Wales, Sydney, New South Wales, Australiaen
dc.identifier.doi10.1111/aas.13318-
dc.identifier.orcid0000-0003-2096-5304-
dc.identifier.pubmedid30648262-
dc.type.austinJournal Article-
local.name.researcherHilton, Andrew K
item.languageiso639-1en-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeJournal Article-
crisitem.author.deptIntensive Care-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

28
checked on Dec 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.