Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/18602
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGonzalvo, Augusto-
dc.contributor.authorFitt, Gregory J-
dc.contributor.authorLiew, Susan-
dc.contributor.authorde la Harpe, David-
dc.contributor.authorVrodos, Nikitas-
dc.contributor.authorMcDonald, Matthew-
dc.contributor.authorRogers, Myron A-
dc.contributor.authorWilde, Peter H-
dc.date2015-06-03-
dc.date.accessioned2018-08-30T06:23:40Z-
dc.date.available2018-08-30T06:23:40Z-
dc.date.issued2015-
dc.identifier.citationBritish journal of neurosurgery 2015; 29(4): 508-12-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/18602-
dc.description.abstractA retrospective study. To correlate the incidence of pedicle-screw (PS) misplacement with the dimensions of the pedicles in the treatment of thoracic spine fractures. The technical challenge of internal fixation with PS in the thoracic spine has been well documented in the literature. However, there are no publications that document the correlation between the pedicle dimensions of the thoracic vertebrae in the preoperative computed tomography scans (CT) and the rate of PS misplacement. All patients who had PSs inserted between the T1 and T12 vertebrae during a 24-month period were included in this study. PS position was assessed on high quality CT scans by two independent observers and classified in 2 categories: correct or misplaced. The transverse diameter, craniocaudal diameter and cross-sectional area of the pedicles from T1 to T12 were measured in the pre-operative CT. During the period of this study 36 patients underwent internal fixation with 218 PS. Of the 218 screws, 184 (84.5%) were correct and 34 (15.5%) were misplaced. Misplacement rate was 33% for pedicles with a transverse diameter less than 5 mm, 10.7% for those with a transverse diameter between 5 and 7 mm and 0% for those with a transverse diameter larger than 7 mm. There was a statistically significant difference in the rate of PS misplacement in pedicles with transverse diameter smaller than 5 mm compared with the others. Also, those with transverse diameter between 5.1 and 7 mm compared with those bigger than 7 mm in diameter. The rate of PS misplacement was higher between T3 and T9 (p < 0.05), which in turn correlated with pedicle transverse diameter. The rate of PS misplacement in the mid thoracic spine (T4-T9) is high and correlates with pedicle transverse diameter.-
dc.language.isoeng-
dc.subjectposterior spinal instrumentation-
dc.subjectprediction of outcome-
dc.subjectspinal tumour-
dc.subjectthoracic spine-
dc.subjecttrauma-
dc.titleCorrelation between pedicle size and the rate of pedicle screw misplacement in the treatment of thoracic fractures: Can we predict how difficult the task will be?-
dc.typeJournal Article-
dc.identifier.journaltitleBritish journal of neurosurgery-
dc.identifier.affiliationDepartment of Neurosurgery, Austin Health, The University of Melbourne, Heidelberg, Victoria, Australia-
dc.identifier.doi10.3109/02688697.2015.1019414-
dc.identifier.pubmedid26037937-
dc.type.austinJournal Article-
local.name.researcherFitt, Gregory J
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.openairetypeJournal Article-
item.grantfulltextnone-
item.languageiso639-1en-
crisitem.author.deptNeurosurgery-
crisitem.author.deptRadiology-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

48
checked on Jan 1, 2025

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.