Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/16372
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFazlollahi, Amir-
dc.contributor.authorMeriaudeau, Fabrice-
dc.contributor.authorGiancardo, Luca-
dc.contributor.authorVillemagne, Victor L-
dc.contributor.authorRowe, Christopher C-
dc.contributor.authorYates, Paul A-
dc.contributor.authorSalvado, Olivier-
dc.contributor.authorBourgeat, Pierrick-
dc.contributor.authorAIBL Research Group-
dc.date2015-10-24-
dc.date.accessioned2016-10-18T03:16:48Z-
dc.date.available2016-10-18T03:16:48Z-
dc.date.issued2015-12-
dc.identifier.citationComputerized Medical Imaging and Graphics 2015; 46(3): 269-276en
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/16372-
dc.description.abstractSusceptibility-weighted imaging (SWI) is recognized as the preferred MRI technique for visualizing cerebral vasculature and related pathologies such as cerebral microbleeds (CMBs). Manual identification of CMBs is time-consuming, has limited reliability and reproducibility, and is prone to misinterpretation. In this paper, a novel computer-aided microbleed detection technique based on machine learning is presented: First, spherical-like objects (potential CMB candidates) with their corresponding bounding boxes were detected using a novel multi-scale Laplacian of Gaussian technique. A set of robust 3-dimensional Radon- and Hessian-based shape descriptors within each bounding box were then extracted to train a cascade of binary random forests (RF). The cascade consists of consecutive independent RF classifiers with low to high posterior probability constraints to handle imbalanced training sets (CMBs and non-CMBs), and to progressively improve detection rates. The proposed method was validated on 66 subjects whose CMBs were manually stratified into "possible" and "definite" by two medical experts. The proposed technique achieved a sensitivity of 87% and an average false detection rate of 27.1 CMBs per subject on the "possible and definite" set. A sensitivity of 93% and false detection rate of 10 CMBs per subject was also achieved on the "definite" set. The proposed automated approach outperforms state of the art methods, and promises to enhance manual expert screening. Benefits include improved reliability, minimization of intra-rater variability and a reduction in assessment time.en
dc.subjectCerebral microbleeden
dc.subjectMulti-scale Laplacian of Gaussianen
dc.subjectRadon transformen
dc.subjectRandom forestsen
dc.subjectSusceptibility-weighted imagingen
dc.titleComputer-aided detection of cerebral microbleeds in susceptibility-weighted imagingen
dc.typeJournal Articleen
dc.identifier.journaltitleComputerized Medical Imaging and Graphicsen
dc.identifier.affiliationCSIRO Digital Productivity Flagship, The Australian e-Health Research Centre, Herston, Queensland, Australiaen
dc.identifier.affiliationLe2I, University of Burgundy, Le Creusot, Franceen
dc.identifier.affiliationRLE, Massachusetts Institute of Technology, MA, USAen
dc.identifier.affiliationDepartment of Nuclear Medicine and Centre for PET, Austin Health, Heidelberg, Victoria, Australiaen
dc.identifier.pubmedurihttps://pubmed.ncbi.nlm.nih.gov/26560677en
dc.identifier.doi10.1016/j.compmedimag.2015.10.001en
dc.type.contentTexten
dc.identifier.orcid0000-0003-3910-2453en
dc.type.austinJournal Articleen_US
local.name.researcherRowe, Christopher C
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-
item.grantfulltextnone-
crisitem.author.deptMolecular Imaging and Therapy-
crisitem.author.deptMolecular Imaging and Therapy-
crisitem.author.deptAged Care-
crisitem.author.deptGeriatric Medicine-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

54
checked on Feb 11, 2025

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.