Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/16240
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLe Roux, Pierre-Yves-
dc.contributor.authorLeong, Tracy L-
dc.contributor.authorBarnett, Stephen A-
dc.contributor.authorHicks, Rodney J-
dc.contributor.authorCallahan, Jason-
dc.contributor.authorEu, Peter-
dc.contributor.authorManser, Renee-
dc.contributor.authorHofman, Michael S-
dc.date2016-08-20-
dc.date.accessioned2016-09-13T01:45:54Z-
dc.date.available2016-09-13T01:45:54Z-
dc.date.issued2016-08-20-
dc.identifier.citationCancer Imaging 2016; 16(1): 24en_US
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/16240-
dc.description.abstractBACKGROUND: Pre-operative evaluation of lung cancer patients relies on calculation of predicted post-operative (PPO) lung function based on split lung function testing. Pulmonary perfusion (Q) PET/CT can now be performed by substituting Technetium-99 m labeling of macroaggregated albumin (MAA) with Gallium-68. This study compares Q PET/CT with current recommended methods of pre-operative lung function assessment. METHODS: Twenty-two patients planned for curative surgical resection (mean FEV1 77 %, SD 21 %; mean DLCO 66 %, SD 17 % predicted) underwent pre-operative Q PET/CT. Sixteen patients also underwent conventional lung scintigraphy. Lobar and lung split PPO lung function were calculated using Q PET/CT and current recommended methods, i.e. calculation based on anatomical segments for lobar function, and conventional perfusion scan for pneumonectomy. Bland-Altman statistics were used to calculate agreement between methods for PPO FEV1 and PPO DLCO. RESULTS: While mean split lobar functions were comparable, there was variation on an individual level between Q PET/CT and the anatomical method, with absolute difference over 5 % and 10 % in 37 % and 11 % of patients, respectively. For lobectomy the mean difference in PPO FEV1 was-1.2, but limits of agreement were-10 to 8.1 %. For DLCO, values were-1.1 % and-9.7 to 7.5 %, respectively. For pneumonectomy, PPO FEV1 values were-0.4 and-5.9 to 5.1 %. For DLCO, values were 0.3 % and-5.1 to 4.6 %. CONCLUSIONS: While anatomic estimation provides "fixed" results, split lobar functions computed with Q PET/CT vary widely, reflecting the intra and inter-individual variability of regional lung function. Further studies to assess the role of Q PET/CT in predicting peri-operative risk in lung cancer patients planned for lobectomy are warranted.en_US
dc.subjectGallium-68en_US
dc.subjectLung canceren_US
dc.subjectPET/CTen_US
dc.subjectPerfusionen_US
dc.subjectSurgeryen_US
dc.titleGallium-68 perfusion positron emission tomography/computed tomography to assess pulmonary function in lung cancer patients undergoing surgeryen_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleCancer Imagingen_US
dc.identifier.affiliationAustin Health, Heidelberg, Victoria, Australiaen_US
dc.identifier.affiliationDivision of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne, Victoria, Australiaen_US
dc.identifier.affiliationNuclear Medicine department, Brest University Hospital, Brest, Franceen_US
dc.identifier.affiliationService de médecine nucléaire, CHRU de Brest, Brest Cedex, Franceen_US
dc.identifier.affiliationThe University of Melbourne, Parkville, Victoria, Australiaen_US
dc.identifier.affiliationDepartment of Surgery, Austin Health, Heidelberg, Victoria, Australiaen_US
dc.identifier.affiliationDepartment of Surgery, Royal Melbourne Hospital and Peter MacCallum Cancer Centre, East Melbourne, Victoria, Australiaen_US
dc.identifier.affiliationDepartment of Cancer Medicine, Peter MacCallum Cancer Centre, St. Andrews Place, East Melbourne, Victoria, Australiaen_US
dc.identifier.affiliationDepartment of Respiratory Medicine, Royal Melbourne Hospital, Parkville, Victoria, Australiaen_US
dc.identifier.pubmedurihttps://pubmed.ncbi.nlm.nih.gov/27544383en_US
dc.identifier.doi10.1186/s40644-016-0081-5en_US
dc.type.contentTexten_US
dc.type.austinJournal Articleen_US
local.name.researcherBarnett, Stephen A
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeJournal Article-
crisitem.author.deptRespiratory and Sleep Medicine-
crisitem.author.deptInstitute for Breathing and Sleep-
crisitem.author.deptThoracic Surgery-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

44
checked on Dec 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.