dc.description.abstractThe ultrasonic cardiac output monitor is a non-invasive, continuous-wave Doppler monitor that can be used to measure cardiac output. Its accuracy and precision in peri-operative and critical care has been assessed with varied results. We conducted a meta-analysis to calculate a pooled mean bias, precision and percentage error for this device. Six studies were suitable for inclusion into a pooled parametric analysis consisting of 320 measurements. The mean weighted bias was -0.39 l.min(-1) (95% CI -0.25 to -0.53 l.min(-1) ), precision 1.27 l.min(-1) and percentage error 42.7% (95% CI 38.5-46.9%). The ultrasonic cardiac output monitor achieved similar agreement with bolus thermodilution to that of other minimally invasive methods of peri-operative cardiac output monitoring, and may have a useful role in cardiac output monitoring.en
dc.language.isoenen
dc.subject.otherCardiac Outputen
dc.subject.otherEchocardiography, Doppleren
dc.subject.otherHumansen
dc.subject.otherMonitoring, Intraoperative.methodsen
dc.subject.otherReproducibility of Resultsen
dc.subject.otherThermodilutionen
dc.titleA meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM).en
dc.typeJournal Articleen
dc.identifier.journaltitleAnaesthesiaen
dc.identifier.affiliationDepartment of Anaesthesia, Austin Hospital, Melbourne, Australiaen
dc.identifier.doi10.1111/j.1365-2044.2012.07311.xen
dc.description.pages1266-71en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/22928650en
dc.type.austinJournal Articleen
local.name.researcherPeyton, Philip J
item.languageiso639-1en-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
crisitem.author.deptAnaesthesia-
crisitem.author.deptInstitute for Breathing and Sleep-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

22
checked on Oct 7, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.